An FMT engineer replies within one working day. Budget prices from tank size and duty. +91 73852 62875WhatsAppsales@fluidmixtech.comExport buyers

Jacketed and limpet coil reactors

Reactors whose temperature is held by a medium flowing outside the shell, in a full jacket, a limpet (half-pipe) coil or a dimple jacket. The right one depends on the medium, its pressure and how fast heat has to move.

An FMT engineer replies within one working dayBudget price from tank size and duty

Limpet coil (half-pipe) wound on a vessel shell in the FMT works
Limpet coil (half-pipe) wound on a vessel shell in the FMT works

Most batch reactions follow a temperature profile: heat up, hold while the heat of reaction is removed, then cool before discharge. How fast that happens depends on three things: the heat transfer area on the shell and bottom, the flow and temperature of the medium outside, and the agitation inside, which keeps renewing the product at the wall.

We build all three common arrangements. A conventional jacket is a second shell around the vessel, simple and economical for steam and water at modest pressure. A limpet coil is a half-pipe welded in a spiral round the shell; the medium flows fast along a fixed path and the coil stands higher pressure, so it is the usual choice for thermic oil and high-pressure steam. A dimple jacket is a thin sheet stamped with dimples and welded to the shell, light and effective at moderate pressure. Where the wall area is not enough, internal coils add more. Our guide jacket vs limpet coil vs dimple jacket compares them in detail.

Where it is used

  • Exothermic reactions that need steady heat removal
  • High-temperature reactions on thermic oil
  • Heating and cooling cycles in batch processing
  • Polymerisation and resin cooking
  • Crystallisation by controlled cooling
  • Holding products at temperature

How FMT builds it

Design codeASME Section VIII or PED on request
Full jacketOn shell and bottom, with nozzles placed to spread the flow
Limpet coilHalf-pipe coil on shell and bottom, in one or more zones
Dimple jacketDimpled sheet welded to the shell
Internal coilAdded where the wall area is not enough for the heat duty
MediaSteam, thermic oil, hot water, cooling water or chilled water
AgitatorSized for heat transfer as well as mixing; anchor with scrapers for viscous batches
MaterialsSS 304 or SS 316 / 316L on the product side
InsulationInsulation and cladding over the jacket on request
Typical arrangement

The red lines show how the impeller moves the liquid. Every FMT unit is sized for its own vessel, product and duty, so yours is drawn for your tank in the offer.

Send your vessel for a drawing
Two vessels with dimple jackets and their nozzles, ready for the next stage
Two vessels with dimple jackets and their nozzles, ready for the next stage
Dimple-jacketed vessel shell finished in the FMT works
Dimple-jacketed vessel shell finished in the FMT works
Limpet coil reactor shells in fabrication
Limpet coil reactor shells in fabrication

What we need to size it

  • Batch volume and the product through the batch: density, viscosity and specific heat
  • Temperature profile: heat-up, reaction and cool-down, and the time allowed for each
  • Heat of reaction, if the reaction gives off or takes in heat
  • Heating and cooling media available, with their temperatures and pressures
  • Design pressure and temperature of the vessel and of the jacket or coil
  • Material of construction, or the chemistry so that we can propose one
Send what you have. A vessel drawing and a short description of the product and duty is enough to start; we ask for anything else we need. Send an enquiry

Common questions

Why choose a limpet coil instead of a jacket?
A limpet coil stands higher pressure than a conventional jacket and forces the medium to flow fast along a fixed path, which gives good heat transfer with thermic oil and avoids dead zones. A conventional jacket is simpler and costs less, and is often the better choice for low-pressure steam or water.
Does the agitator affect heating and cooling time?
Strongly. Heat passes through the wall only as fast as the product next to it is renewed. A better impeller or speed, or an anchor that sweeps the wall in a viscous batch, can shorten heating and cooling more than extra jacket area. We size the agitator for the heat duty as well as for mixing.
Can one reactor be both heated and cooled?
Yes. A jacket or coil can take steam or thermic oil for heating and water or chilled water for cooling, with valves and drains to change over between them. On thermic oil, many plants heat and cool the same oil loop instead of switching media.

Send us your vessel. We size the agitator.

Tank size, product and what the agitator has to do is enough to start. Send a drawing, a datasheet or just a photo of the tank, and we reply with a recommended design and price, or a budget price first if you need one.